Founded in 2010, FLYPOWER is a high-tech enterprise specializing in the research, development, production, and sales of polymer materials. Leveraging its core technological strengths and starting with heat-shrink materials, the company established its Medical Division in 2018, expanding its business and product portfolio into the fields of medical devices and catheters, with the mission of becoming a globally leading supplier of materials for interventional medical devices.

Contact Us No. 77, Bao Nan Road,Nan Lian Community,Long Gang Street,Long Gang District, Shenzhen, Guangdong,518116,China (+86)755 2917 9250 info@flypowermedical.com
Important Information

Medical grade introducer dilator BH-MT-ID

Data Sheet:   BH-MT-ID-EN.pdf
Tags :
Categories:
Applications:

BH-MT-ID Medical‑grade introducer dilator is a supporting component for introducer sheath kits. Equipped with a tapered gradient tip, it is used together with a guidewire to gently expand the puncture channel and facilitate smooth insertion of the sheath into the human body. It is a single‑use sterile accessory for interventional access.

Characteristics:

Medical‑grade PE and PP materials
Support customization of multiple French (Fr) sizes and lengths
Injection‑molded construction with zero leakage risk
Size-coded hubs for different Fr specifications
Compatible with ethylene oxide (EO) sterilization

Approvals/Certifications:

Compliant with ISO 10993

Color:
Colors can be customized

Normal Size

Supplied OD

INCH

MM

6 F

0.087

2.20

8 F

0.104

2.65

10 F

0.131

3.33

12 F

0.157

4.00

14 F

0.183

4.65

16 F

0.207

5.25

18 F

0.234

5.95

20 F

0.260

6.60

Other sizes and the length could be customized on request.

Medical Grade Introducer Dilator BH-MT-ID – Frequently Asked Questions

Q1: What role does the dilator play in an introducer sheath kit, and when is a dedicated dilator design preferable to a generic one?

A1: The dilator is the component that converts a guidewire puncture into a channel large enough to accept the sheath: its tapered gradient tip rides over the guidewire and gently expands the tissue tract so the sheath can follow with minimal insertion force. A dedicated, kit-matched dilator is preferable whenever the sheath it serves has a specific lumen profile – the tip taper, guidewire lumen fit, and dilator-to-sheath transition are designed as a system. Pairing a generic dilator with a mismatched sheath is a common root cause of insertion difficulty, sheath tip buckling, and tissue trauma complaints. We recommend validating the dilator and sheath as a pair rather than qualifying either in isolation.

Q2: How should we evaluate the dilator-to-sheath transition when selecting or qualifying a design?

A2: The transition between the dilator tip and the sheath leading edge is the single most scrutinized feature in the engineering community for this product family. A step, gap, or abrupt shoulder at that junction concentrates insertion force against tissue and is a frequent cause of difficult advancement and vessel trauma. Evaluation should be functional: assemble the dilator into the actual sheath, inspect the transition under magnification, and measure combined insertion force in a representative bench model. A smooth, continuous taper from tip to sheath is the design intent; acceptance criteria based on limit samples from production lots are more meaningful than drawings alone.

Q3: How do we ensure proper guidewire compatibility with the dilator lumen?

A3: The dilator lumen must pass the intended guidewire freely across its full length, including the tip section where the lumen is smallest. Verify fit with the actual wire specified for your procedure – nominal wire size matching is not sufficient, because wire tolerances, coatings, and any pre-shaped tip behavior affect passage. Excessive clearance allows the tip to gap away from the wire and can create a tissue-catching step; insufficient clearance increases friction and risks wire damage. We recommend a passage-force check with your production wire as part of kit qualification, and early discussion with our engineering team if a non-standard wire lumen is needed.

Q4: What should we pay attention to regarding the dilator hub and its locking interface with the sheath?

A4: The hub serves two functions: it is the gripping and pushing interface during insertion, and – where a locking feature is present – it secures the dilator to the sheath so the pair advances as one unit. Key checks are hub-to-sheath engagement security (accidental disengagement mid-insertion separates the taper and creates a step), size-coding legibility for fast identification in the procedure room, and hub strength under the insertion and twisting forces of actual technique. Functional engagement and disengagement testing with the mating sheath, under both dry and wet conditions, is recommended as part of qualification.

Q5: What are the typical failure modes of introducer dilators, and how can they be mitigated at the design stage?

A5: The most frequently reported issues are tip damage – burring, flashing, or deformation of the tapered tip from handling or transit – kinking of the dilator shaft when the access path is flexed, guidewire hang-up inside the lumen, hub-to-sheath disengagement during insertion, and difficulty withdrawing the dilator after sheath placement. Mitigation strategies include tip-protective packaging, shaft stiffness appropriate to the access anatomy, verified wire-lumen fit, a robust locking interface and user technique steps defined in the kit IFU. Identification and mitigation of these risks in the finished device – including biological evaluation, sterilization validation, and process validation – fall under the device manufacturer’s responsibility.

Q6: Which materials and devices is the dilator commonly used with, and are there compatibility concerns to verify?

A6: The dilator is routinely paired with introducer sheaths, standard guidewires, and syringes or accessories connected at the hub. The PE and PP construction is chemically resistant to bodily fluids, common disinfectants, and most agents encountered in interventional access, so chemical compatibility is rarely the limiting factor. The more relevant checks are mechanical: lumen friction with your specific guidewire coating, interface fit with the mating sheath, and behavior of any lubricant applied in your kit preparation steps. Any interaction with device coatings or agents in your actual procedure kit should be confirmed through your own compatibility testing before design freeze.

Q7: Which sterilization methods are suitable and are there any we should be cautious about?

A7: Our product data confirms compatibility with ethylene oxide (EO) sterilization, which is the standard method for this product family. A caution from the wider polymer literature: polypropylene in particular is sensitive to radiation-induced oxidative degradation, so gamma or e-beam methods should not be assumed interchangeable with EO without supporting data on the finished component. Steam sterilization is generally not applicable to this material class. Sterilization method selection, cycle development, residual control – including EO residual limits where relevant – and validation to the applicable standards remain the responsibility of the finished device manufacturer.

Q8: Does the dilator’s ISO 10993 and compliance mean our finished device is automatically approved or biocompatible?

A8: No. We supply a component dilator only. ISO 10993 and data apply to the materials of construction and provide supporting evidence for your regulatory file, but they do not constitute approval of a finished medical device, nor do they transfer to your device by default. Biological evaluation of the final device, sterilization validation, process validation, and all regulatory submissions remain entirely the responsibility of the device manufacturer. We make no claims about finished-device performance and we recommend that downstream marketing materials do not imply regulatory approval based on component-level data.

Q9: How should the dilators be stored, and what handling precautions apply?

A9: Store in the original sealed packaging in a cool, dry environment away from direct UV exposure. The principal storage risks are mechanical and center on the tapered tip: packaging should prevent contact loads on the tip, and cartons should not be stacked in ways that transmit compression to the distal end, since tip deformation directly degrades insertion performance. The materials are environmentally stable under normal warehouse conditions, but we recommend defining storage conditions and any retest intervals within your own quality management system, and performing visual inspection – with particular attention to tip condition – before use, particularly for long-held stock.

Q10: What customization and secondary operations are possible and what should we watch out for?

A10: Customization options include French size, length, guidewire lumen specification, hub size-coding, and custom colors, produced to drawing. Because the dilator is an injection-molded component whose tip geometry is functionally critical, post-molding modification of the tip or taper – trimming, grinding, or re-forming – is generally not advisable, as it directly changes insertion behavior. Marking on the hub may be possible with suitable inks and should be discussed at the quotation stage. Any modification beyond the as-supplied configuration should be validated by the party performing it, including a functional insertion check after modification.

Q11: What documentation and incoming inspection should we plan for when qualifying this dilator as a production component?

A11: Each lot is supplied with a Certificate of Analysis and full lot traceability. For qualification, we recommend an incoming inspection plan covering visual condition under magnification – with particular attention to tip burrs, molding flash, and parting-line condition at the taper – dimensional verification of the tip and lumen, and functional checks on a sample basis: guidewire passage, dilator-to-sheath assembly and transition smoothness, and hub engagement. Tip and transition defects are the most common escape modes for this product family, so acceptance criteria with agreed limit samples are strongly recommended rather than dimensional checks alone. A supplier quality agreement covering specification control, change notification, and nonconformance handling is advisable for OEM/ODM programs.

Q12: What should we expect regarding MOQ, lead time, customization, and long-term supply continuity?

A12: MOQ and lead time depend on whether the configuration is a standard item or a custom build – custom French sizes, lengths, lumen specifications, and hub colors can be produced to drawing, with terms confirmed per quotation. For program security, we recommend blanket or scheduled orders, agreed safety stock for long-lead custom items, and early involvement of our engineering team before design freeze so that specifications are locked prior to validation. Where the dilator is supplied as part of a sheath kit program, aligning both components under a single quality agreement simplifies change control. Supply continuity, specification changes, and end-of-life notification can all be governed under a formal quality agreement with your procurement team.