Founded in 2010, FLYPOWER is a high-tech enterprise specializing in the research, development, production, and sales of polymer materials. Leveraging its core technological strengths and starting with heat-shrink materials, the company established its Medical Division in 2018, expanding its business and product portfolio into the fields of medical devices and catheters, with the mission of becoming a globally leading supplier of materials for interventional medical devices.
Contact Us No. 77, Bao Nan Road,Nan Lian Community,Long Gang Street,Long Gang District, Shenzhen, Guangdong,518116,China (+86)755 2917 9250 info@flypowermedical.comBH-MT-PTFE-CW PTFE coated stainless steel wire is made of high-quality stainless steel with a PTFE coating. The lubricious surface reduces friction in catheter mandrel, guidewire and coiling applications.
Extremely low surface friction coefficient ensures smooth instrument advancement and manipulation, reducing tissue damage
PTFE is chemically inert and resistant to bodily fluids and disinfectants
Anti-coagulant properties reduce the risk of intraoperative thrombosis
The stainless steel substrate provides excellent push force and torque transmission capabilities
Compatibility with ethylene oxide (ETO) sterilization
Compliant with ISO 10993
|
Model |
Stainless Steel OD |
Finished OD |
||
|
Inch |
mm |
Inch |
mm |
|
|
BH-MT-PTFE-CW-0.14 |
0.028 ± 0.005 |
0.14 |
0.0061±0.0002 |
0.155 ± 0.005 |
|
BH-MT-PTFE-CW-0.15 |
0.040 ± 0.005 |
0.15 |
0.0065±0.0002 |
0.165 ± 0.005 |
|
BH-MT-PTFE-CW-0.16 |
0.055 ± 0.005 |
0.16 |
0.0069±0.0002 |
0.175 ± 0.005 |
Customized dimensions are available on request.
Q1: When should we choose PTFE coated stainless steel wire instead of bare stainless wire or a Nitinol core?
A1: PTFE coated stainless steel wire is typically selected when you need the push force and torque transmission of a stainless substrate combined with a lubricious surface – classic examples are catheter manufacturing mandrels, guidewire cores, and coiling applications where the wire must slide against polymer tubing or tissue-contact surfaces. Bare stainless wire is sufficient where friction is irrelevant; Nitinol cores are preferred where kink resistance and superelasticity dominate. If your primary pain point is insertion force, mandrel release, or surface drag, the coated wire is usually the more economical solution than redesigning around a different core alloy. As with any material substitution, we recommend bench verification in your actual assembly before design freeze.
Q2: How does a PTFE coated wire compare with a hydrophilic coated guidewire and how should we choose?
A2: The two coatings serve different design intents. PTFE provides a durable, dry lubricious surface with very low friction that does not require activation and remains stable over shelf life and repeated handling. Hydrophilic coatings become extremely slippery when wet but add process complexity – hydration steps, packaging considerations, and coating durability management. For manufacturing aids such as mandrels, and for guidewires where predictable handling and storage stability matter, PTFE is generally the pragmatic choice; for devices whose clinical value proposition depends on lowest-possible wet friction in tortuous anatomy, hydrophilic may be justified. The comparison should be made at device level, not from coating data alone.
Q3: What should we pay attention to when using this wire as a mandrel in catheter reflow or lamination processes?
A3: Three practical points dominate. First, protect the coating during setup: clamping with serrated or unlined metal jaws is the most common cause of mandrel scoring. Second, control insertion and extraction force – a damaged mandrel surface transfers defects to the catheter ID. Third, verify that your reflow temperature and dwell time are compatible with the complete mandrel assembly. Because the wire functions as a process tool in this scenario, we recommend defining incoming acceptance criteria and a periodic inspection routine for mandrel surface condition, since mandrel wear is a frequent root cause of tubing ID defects.
Q4: Can the wire be welded, soldered, crimped, or adhesively bonded at its ends?
A4: Mechanical termination methods such as crimping, swaging, and laser welding to stainless components are routine, but the PTFE coating must be locally removed from the joint area first – coating trapped in a weld or crimp interface compromises joint integrity. Adhesive bonding directly onto PTFE is unreliable without surface treatment; industrial practice uses plasma treatment or chemical etching of the bond zone, followed by a suitable adhesive system. Termination process development and joint validation are part of your process scope and we recommend verifying joint strength after sterilization and aging, not only as-built.
Q5: What are the typical failure modes of PTFE coated wire and how can they be mitigated at the design stage?
A5: The most frequently reported issues are coating abrasion and scoring from metal-on-metal contact, flaking or delamination where the wire is bent below its practical minimum radius or sharply kinked during handling, and particulate generation at points of repeated rubbing. Mitigation strategies include specifying bend radii generously in the device geometry, using lined or polymer jaws in assembly tooling, controlling handling to prevent kinks, and inspecting high-contact zones during process development. If any coating fragment could migrate within the finished device, that scenario should be captured in your ISO 14971 risk analysis – responsibility for which rests with the device manufacturer.
Q6: Which materials is the coated wire commonly used with, and are there compatibility concerns to verify?
A6: The wire is routinely paired with Pebax, nylon, and other thermoplastic catheter jackets during reflow, with PTFE and PI liners, and with stainless steel or Nitinol guidewire components. The PTFE surface is chemically inert and resistant to bodily fluids and common disinfectants, so chemical compatibility is rarely the limiting factor; the more relevant checks are thermal (reflow windows), mechanical (contact abrasion against metal edges), and cleanliness-related (particulate behavior in your specific assembly). Any drug, coating, or adhesive interaction in your actual build should be confirmed through your own compatibility testing before design freeze.
Q7: Which sterilization methods are suitable and are there any we should be cautious about?
A7: Our product data confirms compatibility with ethylene oxide (EtO) sterilization. A point worth flagging from the wider engineering literature: PTFE is among the more radiation-sensitive polymers, and gamma or e-beam exposure can degrade the coating and alter its friction behavior – so radiation-based methods should not be assumed interchangeable with EtO without supporting data. Steam compatibility depends on the complete device configuration rather than the wire alone. Sterilization method selection, cycle development, residual control, and validation to the applicable standards remain the responsibility of the finished device manufacturer.
Q8: Does the wire’s ISO 10993 and compliance mean our finished device is automatically approved or biocompatible?
A8: No. We supply a component wire only. ISO 10993 and data apply to the materials of construction and provide supporting evidence for your regulatory file, but they do not constitute approval of a finished medical device, nor do they transfer to your device by default. Biological evaluation of the final device, sterilization validation, process validation, ISO 14971 risk analysis, and all regulatory submissions remain entirely the responsibility of the device manufacturer. We make no claims about finished-device performance and we recommend that downstream marketing materials do not imply regulatory approval based on component-level data.
Q9: How should the coated wire be stored, and what handling precautions apply to spooled material?
A9: Store the wire in its original packaging in a cool, dry environment away from direct UV exposure. For spooled material, the key risks are mechanical rather than environmental: avoid tightening, re-spooling, or bending the wire below its natural coil set, and protect spool flanges from impact that could flatten or kink wire at the spool edge. Both the stainless substrate and the PTFE coating are environmentally stable, but we recommend defining storage conditions and any retest intervals within your own quality management system, and performing visual and dimensional inspection before use, particularly for long-held stock.
Q10: What secondary operations can be performed on the wire and what should we watch out for?
A10: Common secondary operations include precision cutting to length, local coating stripping for termination or grounding points, end grinding or shaping, and straightening of spooled material. The recurring caution is coating integrity: cutting and stripping tools must be sharp and aligned, because torn rather than cleanly cut coating edges can initiate flaking in service. Any grinding or shaping should be followed by an appropriate cleaning and inspection step. Because secondary processing modifies the component as supplied, its effect on dimensions, surface condition, coating continuity, and cleanliness should be validated by the party performing the operation.
Q11: What documentation and incoming inspection should we plan for when qualifying this wire as a production component?
A11: Each lot is supplied with a Certificate of Analysis and full lot traceability. For a coated wire, we recommend an incoming inspection plan that goes beyond dimensions: visual inspection under magnification for coating scoring, pinholes, or exposed substrate; verification of finished diameter with appropriate gauging;, where the application justifies it, periodic checks of coating adhesion and continuity per your sampling plan. Coating defects are the most common escape mode for this product family, so magnification-based visual criteria with limit samples are strongly recommended. A supplier quality agreement covering specification control, change notification, and nonconformance handling is advisable for OEM/ODM programs.
Q12: What should we expect regarding supply format, MOQ, lead time, customization, and long-term supply continuity?
A12: The wire can be supplied on spools or as precision cut lengths; beyond the standard size range, customized substrate diameters, finished diameters, and colors can be produced to drawing, with MOQ and lead time confirmed per quotation. For program security, we recommend blanket or scheduled orders, agreed safety stock for long-lead custom items, and early involvement of our engineering team before design freeze so that specifications are locked prior to validation. Supply continuity, specification changes, and end-of-life notification can all be governed under a formal quality agreement with your procurement team.