Founded in 2010, FLYPOWER is a high-tech enterprise specializing in the research, development, production, and sales of polymer materials. Leveraging its core technological strengths and starting with heat-shrink materials, the company established its Medical Division in 2018, expanding its business and product portfolio into the fields of medical devices and catheters, with the mission of becoming a globally leading supplier of materials for interventional medical devices.
Contact Us No. 77, Bao Nan Road,Nan Lian Community,Long Gang Street,Long Gang District, Shenzhen, Guangdong,518116,China (+86)755 2917 9250 info@flypowermedical.comBH-MT-PAS Peel‑Away sheath introducer serves as working access for interventional procedures. It can be split and peeled off after device implantation to avoid limitations of conventional sheath withdrawal. Featuring stable tearing performance, kink‑resistance, low‑friction and X‑ray visibility, it is widely used for pacemaker lead implantation, central venous access and minimally invasive drainage interventions.
Medical‑grade PTFE and Pebax materials
Support customization of multiple French (Fr) sizes and lengths
Injection‑molded construction with zero leakage risk
Color‑coded hubs for different Fr specifications
Compatible with ethylene oxide (EO) sterilization
Compliant with ISO 10993
|
Normal Size |
Supplied OD |
|
|
INCH |
MM |
|
|
6 F |
0.087 |
2.20 |
|
8 F |
0.104 |
2.65 |
|
10 F |
0.131 |
3.33 |
|
12 F |
0.157 |
4.00 |
|
14 F |
0.183 |
4.65 |
|
16 F |
0.207 |
5.25 |
|
18 F |
0.234 |
5.95 |
|
20 F |
0.260 |
6.60 |
The length could be customized on request.
Q1: When should we specify a peel-away sheath instead of a conventional fixed sheath with withdrawal?
A1: A peel-away sheath is typically specified when the implanted device – for example a pacemaker lead or a drainage catheter – has a hub, connector, or feature at its proximal end that prevents a conventional sheath from being withdrawn over it. The sheath provides working access during the procedure and is then split and removed in two halves. The trade-offs are that the sheath is single-access by nature, the peeling step adds a user technique dependency, and tear behavior must be consistent. If your device can tolerate over-the-wire sheath withdrawal, a conventional sheath may be simpler; where it cannot, peel-away is the standard solution. The choice should be confirmed through procedure-level simulation rather than component data alone.
Q2: How should we select the sheath size relative to the device being delivered?
A2: Sizing should be driven by the outer profile of the largest device or connector that must pass through the sheath, plus a functional allowance for friction, coating drag, and any curvature in the access path – not by nominal size matching alone. Undersizing is a common root cause of difficult device passage and insertion damage; oversizing unnecessarily increases the access puncture. We recommend verifying device passage, insertion force and withdrawal behavior with your actual device in bench simulation before locking the specification. French size and length can both be customized to drawing, so an early discussion with our engineering team before design freeze is worthwhile.
Q3: How is consistent tearing performance achieved, and how should we evaluate it?
A3: Peel-away performance depends on the interaction of material selection, the engineered tear line geometry, and process control – this is why a construction with controlled tear features is used rather than post-scored generic tubing. For evaluation, we recommend a functional tear test as part of your incoming or qualification testing: initiate the peel at the hub, split the sheath fully, and assess initiation force, tear path straightness, edge condition, and complete separation without fragments. Because tear performance is a functional property of the finished component, acceptance criteria with limit samples from actual production lots are far more meaningful than material data alone.
Q4: What should we consider when integrating the sheath into a procedural kit with dilators and guidewires?
A4: The practical points are interface fit and sequence. Verify the dilator-to-sheath transition is smooth – a step or gap at the dilator tip is a frequent cause of insertion difficulty and vessel trauma complaints. Confirm the guidewire diameter used in your procedure passes freely through the dilator. And define the assembly order and any preparation steps in your kit IFU. We supply the sheath as a component; dilator and guidewire pairing, kit configuration, and the associated usability validation are the kit manufacturer’s responsibility, and we recommend involving us early if a custom dilator interface is needed.
Q5: What are the typical failure modes of peel-away sheaths, and how can they be mitigated at the design stage?
A5: The most frequently discussed issues are premature or unintended splitting during insertion, difficulty initiating the peel at the end of the procedure, jagged tear edges or incomplete separation, hub wing fracture during peeling, and kinking of the sheath body at the access site under anatomical flexion. Mitigation strategies include selecting a design with controlled tear initiation geometry, validating insertion and peel forces with your actual devices and user technique, ensuring hub wings are robust to the required peel force and respecting the access angle limits of the anatomy. Identification and mitigation of these risks in the finished device falls under the device manufacturer’s ISO 14971 risk management process.
Q6: The sheath is constructed from PTFE and Pebax – what does that mean for device passage and material compatibility?
A6: The PTFE-based inner surface gives the lumen its low-friction character, which is directly relevant to passage force when leads or catheters – particularly coated or soft-durometer devices – are advanced and withdrawn through the sheath. The materials of construction are chemically resistant to bodily fluids, common disinfectants, and most agents encountered in interventional procedures, so chemical compatibility is rarely the limiting factor. The more relevant checks are mechanical (passage and peel forces with your specific device coatings) and cleanliness-related. Any interaction with device coatings, lubricants, or agents in your actual procedure kit should be confirmed through your own compatibility testing before design freeze.
Q7: Which sterilization methods are suitable and are there any we should be cautious about?
A7: Our product data confirms compatibility with ethylene oxide (EO) sterilization, which is the standard method for this product family. A caution worth flagging from the wider polymer literature: PTFE is among the more radiation-sensitive polymers, and gamma or e-beam exposure can degrade fluoropolymer components and alter friction behavior – so radiation-based methods should not be assumed interchangeable with EO without supporting data on the finished component. Steam sterilization is generally not applicable to this material combination. Sterilization method selection, cycle development, residual control – including EO residual limits where relevant – and validation to the applicable standards remain the responsibility of the finished device manufacturer.
Q8: Does the sheath’s ISO 10993 and compliance mean our finished device is automatically approved or biocompatible?
A8: No. We supply a component sheath only. ISO 10993 and data apply to the materials of construction and provide supporting evidence for your regulatory file, but they do not constitute approval of a finished medical device, nor do they transfer to your device by default. Biological evaluation of the final device, sterilization validation, process validation, ISO 14971 risk analysis, and all regulatory submissions remain entirely the responsibility of the device manufacturer. We make no claims about finished-device performance and we recommend that downstream marketing materials do not imply regulatory approval based on component-level data.
Q9: How should the sheaths be stored, and what handling precautions apply?
A9: Store in the original sealed packaging in a cool, dry environment away from direct UV exposure. The principal storage risks for this product family are mechanical: avoid stacking loads that compress the sheath body or stress the hub wings, and avoid conditions that could deform the tear line geometry, since a compromised tear line can cause premature splitting in use. The materials are environmentally stable under normal warehouse conditions, but we recommend defining storage conditions and any retest intervals within your own quality management system, and performing visual inspection before use, particularly for long-held stock.
Q10: What customization and secondary operations are possible and what should we watch out for?
A10: Customization options include French size, length, hub color coding, and custom colors, produced to drawing. Because the sheath is a molded component with an engineered tear feature, post-molding secondary operations on the sheath body – trimming, scoring, or machining – are generally not advisable, as they can disturb the tear line and change split behavior. Marking or printing on the hub may be possible with suitable inks and should be discussed at the quotation stage; note that fluoropolymer surfaces are bond- and print-resistant without surface treatment, which constrains marking options. Any modification beyond the as-supplied configuration should be validated by the party performing it, including a functional tear check after modification.
Q11: What documentation and incoming inspection should we plan for when qualifying this sheath as a production component?
A11: Each lot is supplied with a Certificate of Analysis and full lot traceability. For qualification, we recommend an incoming inspection plan covering visual condition – with particular attention to tear line integrity, molding flash, and hub wing condition – dimensional verification of the sheath body and lumen, and a functional tear test on a sample basis with agreed limit samples. Functional properties such as tear behavior and hub robustness are the most common escape modes for this product family, so sampling plans should cover them explicitly rather than relying on dimensional checks alone. A supplier quality agreement covering specification control, change notification, and nonconformance handling is advisable for OEM/ODM programs.
Q12: What should we expect regarding MOQ, lead time, customization, and long-term supply continuity?
A12: MOQ and lead time depend on whether the configuration is a standard item or a custom build – custom French sizes, lengths, and hub colors can be produced to drawing, with terms confirmed per quotation. For program security, we recommend blanket or scheduled orders, agreed safety stock for long-lead custom items, and early involvement of our engineering team before design freeze so that specifications are locked prior to validation. Supply continuity, specification changes, and end-of-life notification can all be governed under a formal quality agreement with your procurement team.