Founded in 2010, FLYPOWER is a high-tech enterprise specializing in the research, development, production, and sales of polymer materials. Leveraging its core technological strengths and starting with heat-shrink materials, the company established its Medical Division in 2018, expanding its business and product portfolio into the fields of medical devices and catheters, with the mission of becoming a globally leading supplier of materials for interventional medical devices.

联系我们 No. 77, Bao Nan Road,Nan Lian Community,Long Gang Street,Long Gang District, Shenzhen, Guangdong,518116,China (+86)755 2917 9250 [email protected]
重要信息

Medical grade LDPE heat shrink tubing BH-MT-2-H

Applications:

BH-MT-2-H is a 2:1 shrink ratio medical grade heat shrinkable tubing made of medical grade polyolefin. Compared with BH-MT-2 medical tubing, it has thicker wall thickness, and can satisfy the stricter requirement of electrical insulation and the mechanical property of abrasion resistance. It is usually designed for the insulation protection of abdominal medical devices.

Characteristics:

Shrink ratio: 2:1
Low shrink temperature
High transparency, soft
Good physical, chemical, and electrical properties
Excellent electrical insulation properties
Suitable for gamma (γ) ray and ethylene oxide (ETO) sterilization

Operating Temperature:

Operating Temperature: -30°C to +105°C
Initial Shrinkage Temperature: ≥60°C
Minimum Temperature for Complete Retraction: 110°C

Approvals/Certifications:

ISO 10993, USP Class VI and RoHS compliant

Color:
Black, clear(other colors are available on request)

Model

Supplied

Recovered(mm)

Package

(Meters/Spool)

Mini. ID

W.T

ID

W.T

BH-MT-2-H-1.2

1.2

0.20±0.05

≤0.6

0.41±0.08

200

BH-MT-2-H-1.6

1.6

0.20±0.05

≤0.8

0.43±0.08

200

BH-MT-2-H-2.4

2.4

0.25±0.05

≤1.20

0.51±0.08

200

BH-MT-2-H-3.2

3.2

0.25±0.05

≤1.6

0.51±0.08

200

BH-MT-2-H-4.8

4.8

0.25±0.05

≤2.40

0.51±0.08

100

BH-MT-2-H-6.4

6.4

0.30±0.05

≤3.2

0.64±0.08

100

BH-MT-2-H-9.5

9.5

0.30±0.05

≤4.8

0.64±0.08

50

BH-MT-2-H-12.7

12.7

0.30±0.05

≤6.40

0.64±0.08

50

BH-MT-2-H-19.1

19.1

0.35±0.05

≤9.5

0.76±0.08

50

BH-MT-2-H-25.4

25.4

0.45±0.05

≤12.7

0.89±0.08

50

 Customized dimensions and heat shrink ratio for your special applications on request.

Cross Reference:
Tyco-Raychem: MT-5000

Property

Test Method

Typical Data

Longitudinal change %

ASTM D 2671

-10~+10

Concentricity

ASTM D 2671

≥70%

Tensile strength/MPa

ASTM D 638

≥10.3

Elongation at break/%

ASTM D 638

≥120

Low temperature flexibility(-55°C/4h)

ASTM D2671

No cracking

Heat shock(180˚C/4 h)

ASTM D2671

No cracking

Dielectric strength/kV/mm

ASTM D 2671

≥19.7

Volume resistivity/Ω·cm

ASTM D 876

≥1015

FAQ: BH-MT-2-H — Medical Grade LDPE Heat Shrink Tubing

Written for medical device R&D and process engineers, OEM/ODM partners and sourcing teams working on laparoscopic and abdominal surgical instruments, electrosurgical devices and other invasive assemblies. This FAQ focuses on selection and drop-in replacement migration (including from Tyco-Raychem MT-5000), thermal processing practice, failure modes, substrate compatibility, sterilization, compliance boundaries and sourcing. All physical properties, dimensions, shrink ratio and test values are published in the product datasheet and are intentionally not repeated here — refer to the BH-MT-2-H product page for the full specification. MT-2000™ and MT-5000™ are trademarks of TE Connectivity; references are for compatibility comparison only and do not imply affiliation or endorsement.

1. Selection & Migration

Q1. What should we verify before selecting BH-MT-2-H — or migrating to it as a direct drop-in replacement for Tyco-Raychem MT-5000?

A1. BH-MT-2-H is a thicker-wall medical polyolefin grade positioned as a direct drop-in replacement for MT-5000, typically chosen where insulation protection of abdominal surgical devices demands both electrical insulation and abrasion resistance. Verify four checkpoints.
(1) Fit at both states: the supplied ID must slide over your component freely, and the recovered ID must grip it with positive interference — cross-check our datasheet size bands against your drawing rather than relying on the nominal size name.
(2) Wall and profile: this grade is the thicker-wall member of the BH-MT-2 family, so confirm the recovered wall and the OD it adds to your instrument against your profile budget, and note that wall-thickness tolerance and concentricity directly affect insulation uniformity — use the tolerance band, not the nominal.
(3) Process prerequisites: recovery happens at low temperatures (see datasheet), gentle on heat-sensitive components, but you still need controlled, uniform heating equipment.
(4) Migration: even for a true drop-in, run side-by-side recovery trials against the incumbent on your real build, confirm your process window needs no more than minor adjustment, and complete your own IQ/OQ/PQ and design-change assessment before release; evaluation samples are available for exactly this work.

2. Thermal Processing & Failure Modes

Q2. Which heating equipment suits this tubing, and what failure modes should we watch for?

A2. Use validated convection ovens, automated hot-air rings or infrared stations with closed-loop temperature control and fixed feed rates. Handheld heat guns are the leading cause of scrap and field failures: they create hot spots that locally over-shrink or degrade the material while adjacent zones remain unrecovered, and they make results operator-dependent — unacceptable in a validated medical process. When shrinking over heavy metal shafts or instrument bodies, pre-heat the core so the sleeve is not heat-sinking on the inside. Failure modes frequently reported with medical polyolefin sleeves:
(1) cracking or splitting — usually initiated at sharp edges, burrs, laser-cut features or steps, or driven by thermal peaks and over-arrested recovery that traps residual hoop stress; deburr all edges and avoid sizing that forces the sleeve to free-recover against a much smaller mandrel;
(2) whitening or chalky marks — stress whitening from kinking, over-stretching during installation or excessive local strain; treat as a rejectable defect, it signals damaged polymer;
(3) bubbles or blisters — air trapped at the ends or heating too fast; shrink progressively from center to end so air escapes;
(4) uneven recovery or surface waviness — non-uniform heat distribution; rotate the part or use 360° heating; (5) longitudinal shift — this family changes length during recovery (see datasheet), so position the sleeve with allowance and verify end positions on first articles before locking the process.

3. Substrate Compatibility

Q3. What should we know about contact with instrument substrates, metals and medical adhesives?

A3. The low recovery temperature makes this tubing friendly to mixed-material builds — it can typically be recovered over stainless steel shafts, Nitinol components and many thermoplastic constructions (PEBAX, Nylon, PU) without damaging them, but verify on your exact stack since softening behavior varies widely by grade and durometer. Over metals, surface condition is the hard precondition: deburr, polish or tumble every edge, weld seam and step the sleeve will cross, because a sharp feature under recovery hoop stress becomes a crack-initiation site. Keep contact surfaces clean — machining oils, polishing compounds and unflashed isopropanol residues degrade recovery quality and can seed blisters. On adhesion: LDPE is a low-surface-energy polyolefin — medical adhesives, primers and overmolding materials will not bond reliably to it without surface treatment (corona, plasma or chemical primer). If your design bonds or overmolds over the sleeve, plan that treatment step explicitly or contact us to discuss options.

4. Chemical Exposure & Material Declarations

Q4. Any precautions for chemicals and disinfectants, and what declarations are available?

A4. The tubing tolerates routine hospital cleaning and common disinfectants such as alcohols, but polyolefins are less chemically inert than fluoropolymers: avoid prolonged contact with strong oxidizing agents and aromatic or chlorinated solvents. If your device sees repeated exposure to a specific agent — for example aggressive reprocessing chemistries on reusable instruments — share the chemistry, concentration and exposure cycle with us and we will support a compatibility assessment. On documentation: the material complies with ISO 10993, USP Class VI and RoHS (see datasheet), and we support your material-declaration work with composition statements and material test reports. Raise any substance-level declaration needs (SVHC, REACH, specific restricted substances) in the RFQ so the correct documentation is prepared from the start.

5. Sterilization

Q5. Which sterilization methods are supported, and what changes should we expect with repeated cycles?

A5. The datasheet states support for gamma irradiation and ethylene oxide (EtO) sterilization environments. Two honest boundary notes.
(1) Steam autoclaving and dry-heat sterilization are not supported by this material family: LDPE’s service temperature is far below autoclave conditions, and a steam cycle will distort or re-shrink the recovered sleeve — if your device requires steam reprocessing, ask us about higher-temperature grades instead.
(2) Even with the qualified methods, validate on the recovered sleeve on your actual device across the full intended cycle count: repeated radiation or EtO cycles can shift polyolefin properties, and you should verify dimensional stability (including length), surface condition, grip and — where the sleeve serves as insulation — dielectric integrity after exposure. Creep under residual hoop stress accumulates with cycles, so include the worst-case cycle number in your validation plan rather than a single pass.

6. Application Boundaries

Q6. Where is BH-MT-2-H the right choice — and where is it NOT recommended?

A6. Well suited: insulation protection of abdominal medical devices and similar invasive instruments — laparoscopic and electrosurgical shafts, handles, leads and joints — wherever the design needs the combination of electrical insulation and mechanical abrasion resistance that the thicker wall provides, processed with gentle low-temperature heat, and where a smooth surface finish is required. Use with caution or not recommended: devices that will undergo steam autoclaving or dry-heat reprocessing (see the sterilization question); continuous service at elevated temperatures; applications expecting the sleeve to carry structural or torsional load — it is an insulating jacket, not a structure; assemblies with sharp edges or burrs that cannot be smoothed; and severe sliding abrasion against sharp counter-surfaces, where no polymer sleeve substitutes for design protection. If your application is dominated by high temperature, aggressive chemicals or extreme mechanical abuse, tell us before design freeze and we will point you to the right material family in our range.

7. Regulatory & Electrical Compliance Boundaries

Q7. Does ISO 10993 / USP Class VI compliance — or the published dielectric rating — mean our finished device is approved?

A7. No — and this distinction matters in audits. We supply component tubing only. Material-level compliance with ISO 10993 / USP Class VI supports, but does not replace or constitute, regulatory approval of your finished medical device: biological evaluation of the finished device (ISO 10993-1), sterilization validation, process validation (IQ/OQ/PQ) and risk analysis (ISO 14971) remain the device manufacturer’s responsibility. The same logic applies electrically, and it is critical for this product’s typical use on powered surgical instruments: the dielectric properties in our datasheet are material-level test values, not an electrical safety certification of your instrument. Dielectric withstand (hi-pot), leakage current, creepage and clearance verification on the finished device (for example under the IEC 60601 series where applicable) must be performed and documented by you on the final assembly — including after sterilization and aging, because insulation performance can drift. A single pinhole, nick or processing crack defeats the material rating, so end-of-line electrical inspection is part of realizing it. We do not claim performance beyond the published datasheet.

8. Storage & Aging

Q8. How should the tubing be stored, and does long-term storage affect performance?

A8. Polyolefins are more storage-sensitive than fluoropolymers. Keep the tubing in its original packaging, cool, dry, away from direct sunlight/UV and heat sources: elevated storage temperature can slowly relax the expanded state and reduce available recovery, and UV/ozone ages polyethylene surfaces. Protect against crushing, kinking and edge nicks in handling, and apply first-in-first-out rotation. The datasheet does not assign a fixed shelf life; for lots stored long-term, run a quick recovery check on a sample piece at your qualified settings before releasing the lot to production, and include storage conditions in your incoming-inspection plan. For batch-to-batch consistency assurance on a running program, agree a retained-sample and lot-traceability scheme with us at the supply-agreement stage — it is the cheapest insurance against incoming-material risk.

9. Secondary Processing

Q9. Do you support cutting, custom dimensions, custom colors or special shrink ratios?

A9. Cut-to-length supply is supported, and cut quality is a functional requirement, not a cosmetic one: dull blades and shears leave micro-nicks and jagged rims that act as crack-initiation sites under recovery hoop stress, so we cut with sharp, dedicated tooling and inspect edges — if you cut in-house, hold the same standard. Standard colors are black and transparent, with other colors, special sizes and customized shrink ratios available on request for special applications (see datasheet). Marking and similar secondary operations can be evaluated on request — tell us the requirement in the RFQ and we will confirm feasibility and achievable tolerances. Given the family’s longitudinal change during recovery (see datasheet), also agree whether cut length is specified in the supplied or recovered state — this is a classic source of drawing disputes on replacement programs.

10. Samples, Pilot Batches & Production Ramp

Q10. How do samples and the ramp from trials to mass production work — especially when replacing an incumbent like MT-5000?

A10. Evaluation samples of standard sizes are available so you can qualify the recovery window on your real equipment and components before any commitment — on a replacement program this is where you confirm whether your existing heating recipe transfers unchanged or needs minor adjustment of temperature or dwell. We then support pilot batches through to mass production, with lead times confirmed at quotation; if you are dual-sourcing after experiencing long lead times, allocation or high MOQs on branded medical tubing, share the incumbent specification (dimensional class, recovered wall, color, performance requirements) and we will map the closest equivalent for side-by-side trials. Recommended practice for second-source introduction: keep incoming inspection of first production lots against your qualified reference samples, and retain golden samples from the qualification lots for later lot comparison.

11. RFQ Checklist

Q11. What engineering information should an RFQ include?

A11. For a fast and accurate quotation, please provide: required size (supplied ID and/or recovered ID) and the recovered wall-thickness requirement, including which tolerance is functionally critical; quantity and estimated annual volume; supply form (spool or cut length, with tolerance, and whether length is defined in the supplied or recovered state); color; the application and what sits under the sleeve (component material, diameter range and tolerances, surface condition); the profile budget the recovered sleeve may add; your heating equipment type and process temperature; whether the sleeve must be bonded to or overmolded (i.e., whether surface treatment is planned); sterilization method and number of cycles; electrical requirements if used as insulation (operating voltage and the finished device’s hi-pot level, and whether pinhole/continuity inspection is required); the incumbent specification if this is an MT-5000 replacement or other second-source migration; secondary operations (cutting, marking); compliance documentation required (ISO 10993 / USP Class VI material reports, RoHS and composition declarations); and target price, delivery terms and destination. 

12. Material Declaration, MAF & Change Control

Q12. What should we know about material declarations, MAF files and change control?

A12. Practical points.
(1) We provide material-level documentation — composition statements, RoHS statement and ISO 10993 / USP Class VI material test reports — for your technical file, EU MDR documentation or supplier-qualification records.
(2) Where a device master file (MAF) reference is the right mechanism, we can discuss authorization letters so your regulatory team can reference our material data in your submission; scope is agreed case by case.
(3) What we do not do: we make no claim or commitment on behalf of your finished device — our material documents imply no device-level FDA clearance, no CE conformity, and no device-level biological or electrical safety approval.
(4) Change control: if your regulatory filing requires notification agreements for material or process changes, raise this before design freeze so it is covered in the supply agreement — second-source migrations and material changes are both reportable events in many device filings, and aligning notification duties in the contract is far easier than retrofitting them later.